Sr. no. |
Name of the product |
Description of tests |
Charges w.e.f. 1st April, 2014 |
A. Solar Photovoltaic systems & components |
|
|
|
1 |
Solar Lantern (LED/ CFL ) |
a) Light output and input power measurement |
5000/10000/- |
|
|
b) Light output & compatibility testing of module battery and load for meeting the duty cycle and autonomy |
20000/ |
|
|
c) Full testing as per MNRE / other specs |
|
2 |
Solar street lighting system (LED/CFL) |
a) Light output and input power measurement |
5000/10000/- |
|
|
b) Light output & compatibility testing of module battery and load for meeting the duty cycle and autonomy |
20000/ |
|
|
c) Full testing as per latest MNRE / other specs |
|
3 |
Solar home lighting system (LED/CFL) |
a) Light output and input power measurement |
7000/14000/28000/- |
|
|
b) Light output & compatibility testing of module battery and load for meeting the duty cycle and autonomy |
|
|
|
c) Full testing as per latest MNRE / other specs |
|
4 |
PV Module |
IEC 61215 & IEC 61646 full range (comprising of 18 tests) |
800000/- |
|
Qualification |
|
|
|
testing |
|
|
5 |
PV Module (I-V) |
IEC 60094-1 |
2500/- |
6 |
Solar pump |
As per latest MNRE specification |
10000/- + 2500/- per PV module. |
7 |
Inverter ( Lighting and other small systems) |
As per MNRE/other specifications) |
10000/- |
8 |
Charge controller ( Lighting and other small systems) |
As per MNRE/other specifications) |
10000/- |
9 |
Battery up to 100Ah capacity |
Capacity as per IS 13369, IS 15549 and IS 1651 |
6000/- |
|
|
Efficiency ( Ah & Wh) |
12000/- |
|
|
Self Discharge |
12000/- |
10 |
Battery above 100Ah capacity |
Capacity |
7000/- |
|
|
Efficiency ( Ah & Wh) |
14000/- |
|
|
Self Discharge |
14000/- |
11 |
Inverter up to 15 kVA |
As per IEC standard |
25000/- |
B. Solar Thermal Systems & Components |
|
|
|
12 |
Box type solar cooker |
As per IS 13429 |
4000/- |
13 |
SWH flat plate collectors |
As per IS 12933 |
10000/- |
14 |
SWH ETC type |
As per latest MNRE standards |
10000/- |
please contact: contact@energetica-india.net.